SN-2004
For microwave network applications
Power supply:
-
48 VDC or 220VDC, 20 W
Output:
-
4 manual output valves
pump:
-
DC pump, 4 liter/minute capacity, maximum pressure of at least 1.5 bar
Dehumidification Process:
-
With blue silica-gel, stored in unbreakable/externally replaceable container
Network capabilities:
-
Log file, listing incidents and their occurrence time,
-
Full remote operations including readings, measurements, and controlling
Measurements:
-
Digital pressure meter (mbar)
-
Pump duty time (hours and minutes)
Alarms:
-
High pressure, low pressure, power disconnection
-
Transferable to the supervisory system
Settings:
-
Thresholds for the alarms
-
Turn on and off pressures for the pump
Installation:
-
Wall mount and rack mount options